Type |
| Serveur |
Facteur de forme du produit |
| Rack-mountable-1U |
Server Scalability |
| 2-way |
Front Accessible Bays Qty |
| 10 |
Hot-Swap Bays Qty |
| 10 |
|
| |
UC |
| No CPU |
Qté d'UC max. |
| 2 |
CPU Upgradability |
| Extensible |
|
| |
Taille installée |
| 0 GO / 3072 GO (max.) |
Technologie |
| Mémoire SDRAM DDR4-ECC |
Facteur de forme |
| barrette DIMM 288 broches |
Fentes |
| 24 (total) / 24 (vide) |
Caractéristiques |
| Registered, Load-Reduced DIMM (LRDIMM), 6-channel memory architecture |
|
| |
Type |
| No HDD |
|
| |
Type |
| RAID |
Qté de canaux |
| 8 |
Niveau de stockage RAID |
| RAID 0, RAID 1, RAID 10 |
|
| |
Type |
| Pas de lecteur optique |
|
| |
Cartes mémoire flash supportées |
| carte mémoire SD |
|
| |
Type de moniteur |
| Aucun |
|
| |
Processeur graphique |
| ASPEED Pilot 4 |
Mémoire vidéo |
| 16 Mo |
Interfaces vidéo |
| carte VGA |
|
| |
Ports Ethernet |
| 2 x 10 Gigabit Ethernet |
Contrôleur Ethernet |
| Intel X550 |
Protocole de liaison de données |
| 10 Gigabit Ethernet |
Protocole de gestion à distance |
| SNMP 2, SNMP 3, IPMI 2.0, CLI |
Remote Management Controller |
| Intel Baseboard Management Controller (BMC) |
Caractéristiques |
| Réveil à distance (WiL) |
|
| |
Bays |
| 10 (total) / 10 (free) x hot-swap 2,5" SFF |
Fentes |
| 2 (total)/2 (libre) x UC¦24 (total) / 24 (free) x DIMM 288-pin¦1 (total) / 1 (free) x PCIe 3 x24-half-length, half-height (x16 mode / NCSI support)¦1 (total) / 1 (free) x PCIe 3 x24-three-quarter-length, full-height (x16 mode)¦1 (total) / 1 (free) x mLOM |
Interfaces |
| 2 x USB 3 (2 rear)¦1 x VGA-DB-15 (1 rear)¦1 x séquentiel-RJ-45 (1 rear)¦2 x LAN (10Gigabit Ethernet)-RJ-45 (2 rear)¦1 x management (NIC)-RJ-45 (1 rear)¦1 x KVM (1 in front) |
|
| |
Accessoires inclus |
| 2 x power supply blanking panel, 10 x drive blanking panels, interposer board (8 drive) |
Conformité aux normes |
| CISPR 24, EN55024, AS/NZS 60950-1, ICES-003 Class A, UL 60950-1 Second Edition, ACPI 4.0, EN 60950-1 Second Edition, IEC 60950-1 Second Edition, VCCI Class A, EN61000-3-2, EN61000-3-3, FCC CFR47 Part 15 A, GB 4943-2001, CNS 13438 Class A, CAN/CSA C22,2 No. 60950-1 Second Edition, KN35, Directive 2014/35/EU, Directive 2014/30/EU, AS/NZS CISPR 32 Class A, KN32 Class A, EN 55032 Class A, CISPR 32 Class A, EN 300386 |
|
| |
Type de dispositif |
| Bloc d'alimentation-hot-plug |
Power Redundancy |
| Facultatif |
Power Redundancy Scheme |
| 1+1 |
Qté installée |
| 0 |
Qté max. supportée |
| 2 |
|
| |
Service et soutien |
| Garantie limitée-Remplacement-3 ans-Temps de réponse : prochain jour ouvrable |
|
| |
Largeur |
| 16,9 po |
Profondeur |
| 29,8 po |
Hauteur |
| 1,7 po |
|
| |
Température min. de fonctionnement |
| 41 °F |
Température max. de fonctionnement |
| 95 °F |
Degré d'humidité en fonctionnement |
| 10-90 % (sans condensation) |